Electric locomotive EP08

From SimRail Wiki
Revision as of 02:35, 2 March 2023 by Roman (talk | contribs) (→‎Gallery)
Jump to navigation Jump to search

The following article is about the electric locomotive EU08 / EP08.

EP08, Image by BayFirer

Locomotive in reality

EP08' (type 4Ea and 102E) - passenger electric locomotive of normal gauge of Polish manufacture produced in 1972-1976 in Pafawag plant in Wroclaw. It was called pig by the railwaymen because of the colour with which the vehicles were painted at the factory, or denatured from the paint of the former PKP InterCity paint...

The electrified locomotives of this series were based on the design of the EU06 and EU07 series. The design changes were intended to allow for higher speeds - this was achieved by changing the gear ratio from 79:18 to 77:24. The assumed theoretical top speed of 160 km/h was not introduced because the vehicle then acquires poor handling characteristics and wears out the material more quickly. In addition to the gearbox change, new engines, a different hollow shaft bearing and other upgrades were also used. Type 4Ea locomotives (Nos. 002 - 005) used standard EU07 plain bearings, while the newer Type 102E (Nos. 001 and 006 - 015) were fitted with roller bearings. The original EP08 construction programme envisaged the building of 100 of these cars, but this was not completed. Between 1972 and 1976 Pafawag produced only 15 units (Roman Staszałek lists 14). The end of production was due to the lack of foreign currency to buy bearings abroad [1].

In-game locomotive

EP08

This in-game electric locomotive was added in the 19.02.2023 update and players can run this locomotive on EC trains, and the locomotive offers an alternative to the EU07 electric locomotive.

Parameters of this locomotive

  • Maximum speed 140 Km/h

EP08 serving the relevant connections

Train number Train display

on the map

Departure

station

Destination

station

41102 02:41 Katowice Warsaw
41106 04:41 Katowice Warsaw
41110 06:41 Katowice Warsaw
41114 08:41 Katowice Warsaw
41128 15:41 Katowice Warsaw
41122 12:41 Katowice Warsaw
41126 14:41 Katowice Warsaw
41130 16:41 Katowice Warsaw
41134 18:41 Katowice Warsaw
41138 20:41 Katowice Warsaw
41142 22:41 Katowice Warsaw
41146 00:41 Katowice Warsaw
14101 00:28 Warsaw Katowice
14105 02:28 Warsaw Katowice
14109 04:28 Warsaw Katowice
14113 06:28 Warsaw Katowice
14117 08:28 Warsaw Katowice
14121 10:28 Warsaw Katowice
14125 12:28 Warsaw Katowice
14129 14:28 Warsaw Katowice
14133 16:28 Warsaw Katowice
14137 18:28 Warsaw Katowice
14141 20:28 Warsaw Katowice
14145 22:28 Warsaw Katowice

Cold start procedure

The process of reviving this electric locomotive is identical to that of the EU07 / EP07 locomotive.

  1. Make sure you are in cab A. Open the hatch on the left side of the control panel and switch on the battery.
  2. The battery voltmeter will read approximately 90 volts. The SHP test (automatic safety braking device) will activate. To use it, you must turn the directional lever (blue highlighted) to the forward or reverse position and press the vigilance button.
  3. Turn the cab activation key - right.
  4. Turning off the batteries will activate the differential relay. Hold the unlock key until the signal light goes out. If it does not work, check that the power control wheel and shunt control lever are in the zero position.
  5. Raise the pantographs. Wait for voltage to appear on voltmeter, approximately 3 kV.
  6. Turn on the main switch. If it does not operate, check that none of the overload relays are active and that the main line pressure is greater than 0.35 MPa.
  7. Turn on the converter (blue highlighted). Wait for the charging current to stabilize (yellow highlighted).
  8. Switch on the compressor (blue highlighted). Wait for the main tank to fill. Watch the right gauge.
  9. Turn on the radio and select the desired radio channel.
  10. Set the train brake lever to the drive or fill position. Hold the release button (blue highlighted left) until the main line pressure reaches 0.5 MPa. Observe the centre pressure gauge.
  11. Make sure the hand brakes in both cabs have been released. You should see a yellow label in the window that reads "LUZ".
  12. Release the locomotive brake. Wait for the cylinder pressure to drop to 0 MPa.
  13. Turn the drive control wheel to position ONE. Wait for the brakes to apply (blue signal light goes out) and the starting circuits to close (orange signal light comes on and current appears on the ammeter).
  14. Proceed as quickly as possible through the starting resistor positions and try to drive at positions 0, 28 and 43. Then the traction motors will pass all the current. Keep an eye on the ammeters so you don't exceed 600 amps. On the non-resistance positions you can increase the speed by starting the shunt with the shift handle. Beyond position 28 you can go up to 1200A
  15. To brake, turn both the control wheel and the shunting handle to zero and pull the train brake handle towards you. Depending on the desired braking force, relieve 0.05-0.2 MPa of pressure from the main line. Observe the middle pressure gauge. The left one shows only the pressure in the locomotive brake cylinders [2].

Locomotive malfunctions

  • Alarm/SHP on. Press the vigilance button. If both systems are activated simultaneously, it must be pressed twice. If there is insufficient response to visual and audible warning, emergency braking is activated. If the main line pressure has been successfully reduced below 0.35 MPa, you must set the service brake handle to the drive or fill position and hold the release button until the pressure rises to 0.5 MPa.
    EP07 - ignoring SHP
  • Rare overload of traction motors switched on. If the current exceeds 600 A, the overload relay will trip. Set the control wheel and maneuvering handle to zero. Press the traction motor overload relay unlock button. The red signal light goes out.
EP07 - Traction motor overload
  • Rare compressor overload switched on. This relay will trip if you turn on the compressor before the converter power supply stabilizes. Turn off the compressor and converter. Disable the compressor overload relay. Turn on the converter. Wait for the voltage to stabilize. Switch on the compressor.
EP07 - Compressor overload relay open

Gallery

Reference

  • [1] – Wikipedia link
  • [2] - Forum guide