Translations:How to operate relay line block equipment/13/en
Jump to navigation
Jump to search
Relay block type C
The relay block type C is a non-automatic line block which was developed directly from the classic manual block as it was used in (electro-)mechanical interlockings. Instead of mechanical components, however, all dependencies are realised with relay technology. With this line block, old (electro-)mechanical interlockings can be connected to a relay interlocking without major effort, as the line block equipment in the old, existing interlocking does not have to be completely renewed. The C-type relay block can be equipped with a track vacancy detection system. All operations of this line block must be carried out manually.