Translations:How to operate relay line block equipment/89/en: Difference between revisions
Jump to navigation
Jump to search
Importing a new version from external source |
(No difference)
|
Latest revision as of 00:52, 18 April 2024
Exit lock
Pressing the STOP button while departure permission is displayed will enter a lock into the system that will prevent the setting of an exit into the corresponding track. This operation can be used, for example, during track closures. The departure permission indicator changes to a steady red after operation. The exit lock can be deleted by pressing the Wbl button; the departure permission indicator changes back to steady white light. The STOP button is optional and not installed in every system.